Neck Flange Connected Manometers

Neck Flange Connected Manometers

Technical Specifications:
 
Usage Features  Standard
Measurement range         0 - 0,6 0 - 1,0 0 - 1,6 0 - 2,5
 Bar 0 - 4      0 - 6    0 - 10 0 - 16  
  0 - 25  0 - 40 0 - 60  0 - 100
  0 - 160      
Diaphragm body      Stainless  AISI-316
Diaphragm Stainless  AISI-316
Lower flange Stainless  AISI-316
Sealing element Vito
 
Processing temperature  -40... +150°C Maxsimum + 200°C
Pressure range 0/0,6 ... 0/600 bar
Operating pressure (max.) A maximum of 75% of the Full Cipher Value must not exceed.
Overpressure limit PN x 1,25
Sensitivity class  KL 1,0
Relevance  DIN / ANSI
Optimum range of measurement  0,1 PN ile 0,75 x PN between
Protection class  IP 41
Storage temperatures  -40 ... +70°C
Mechanical shock test load  15 g
Mechanical vibration test  10 Hz ile 150 Hz - 1 oktav/dk.2s / 3 axis

Places of Use: Suitable for corrosive, dirty, high temperature and density fluid media.